Yes, an NDT program should be established whenever an NDT inspection is performed. Specifically, if a contract specifies an inspection standard, code, or specification (such as ASME Section V, AWS D1.5, etc.), having an NDT program is mandatory. This program includes a documented procedure, also known as a written practice, detailing how the company will certify its inspections and NDT procedures according to the inspection requirements. Both the documented procedure and NDT procedures require approval from a Level 3 professional. This Level 3 certification can be held by an internal employee or an external consultant.

Yes, AWS D1.5 states that if performing inspections on Fracture Critical Members (FCM), a Level III must be on site supervising of the Level II’s performing the work. 

Non-FCM inspections do not need a Level III on site per AWS D1.5, but it is never a bad idea to have one around.

An NDT program must include inspector certification requirements, a written practice, and procedures for conducting inspections and NDT tasks. The written practice and NDT procedures should detail the processes and include supporting forms. These documents should conform to the company’s formatting and numbering system and integrate seamlessly into the existing quality management system. Existing quality procedures may need to be revised to incorporate the NDT program effectively.

 

Here are some examples of required documents:

 

Written Practice

  • Certification and Qualification Form
  • Visual Acuity Form
  • Annual Maintenance Review Form
  • Training Program Form

 

NDT Procedures for Each Method

  • Inspection Report
  • Calibration Form

 

We can work with your quality or document control teams to ensure that all documents are cohesive and well-integrated.

 

 

 

Our pricing is based on the time required for each project. Our team is here to help you determine the complexity of your needs. Whether you need to develop sections of a program, update an existing one, or create a new program from scratch, we are equipped to assist. We are committed to delivering high-quality results promptly and affordably. We offer transparent pricing and strive to find the most cost-effective solutions tailored to your requirements. Reach out to us today for our latest pricing information.

Yes, We can assist with both conducting audits and addressing any issues resulting from audit failures.

Our experienced team is skilled and committed to delivering exceptional results. We take pride in building strong partnerships with our customers to safeguard their best interests. As your comprehensive NDT solution provider, we are equipped to handle all your non-destructive testing needs.

We operate remotely from Anniston, Alabama, or on-site at our customers’ locations. Our classes are currently held either at the customers’ facilities or in the conference room at Home2Suites.

Absolutely! We have the equipment and personnel to perform a variety of inspections.  Please Contact Us with your needs. 

Certainly! We offer on-site classes tailored to our clients’ specifications, as well as periodic NDT courses throughout the year. Please contact us to discuss your specific needs.

How Can We Help?

Have more questions? Reach out to us anytime using the contact button below!